High Speed Microplate Shaker

 

Home > Products > Shakers > High Speed Microplate Shaker

 

The Troemner High Speed Micro Plate Shaker is designed to tackle the most difficult shaking applications such as culture bacteria in deep well plates,  lysing cells with detergents or mixing polar and non-polar solutions.

 

In a recent high throughput screening application, an extraction was performed in deep well plates using equal volume of organic and aqueous phases.  In a deep well plate, a full 1.5 ml was efficiently mixed in 2 ml wells using this high speed shaker.

New research techniques have placed higher demands on shaking and vortexing devices where traditional orbital shakers are not satisfactory. High speed shaking or vortexing is needed for such applications as emulsification and cell lysing because liquids are viscous or small vessels are being utilized.

The more viscous a solution, the harder it is to mix or emulsify. The smaller the tube diameter and / or headspace in the vessel, the more difficult it is to mix or emulsify because the solution has little space to increase velocity. Cell lysing is commonly done in deep well microplates with small diameter holes or small micro tubes, and many shaking units do not have enough speed or power to lyse the cells in these vessels.

There is no unit on the market that is designed to operate up to 2500 RPM and is specifically designed to hold deep well blocks, and trays of small diameter test tubes. With a 0.070 offset, the unit is able to reach higher speeds, which increases the vigor of the mixing. The unit has 12 suction cup feet under the base, which prevents the unit from "walking" on the lab bench. The High Speed Micro Plate Shaker can hold up to 7 pounds, which will accommodate many larger blocks used in combinatorial chemistry applications. The unit has a series of spacers on the threaded posts to allow for adjustment from 1/8" up to 5 inches, which allows the user to double or even triple stack micro plates up to 5 inches in height.

The High Speed Micro Plate Shaker is not limited to high throughput screening and combinatorial chemistry applications. Recommend it for any application where emulsification is needed and viscosity or small vessels present a problem.

PRODUCT NUMBERS AND LIST PRICE:

TR-945130

Analog Control 120 volt $3320

TR-945135

Analog Control 230 volt $3320

TR-945170

Digital Control 120 volt $4150

TR-945175

Digital Control 230 volt $4150

 

SPECIFICATIONS

DIMENSIONS: 12.0" W x 15.5" D x 12.8" H
WEIGHT: 50 lbs.
VOLTAGE: 115 volts AC, 50/60 hertz; 230 volts AC, 50/60 hertz
CURRENT: less than 1 amp
POWER: 120 watts
SPEED: 600-2500 rpm
ACCURACY: +/- 25 rpm
ECCENTRIC ORBIT: 0.140" diameter (0.070 offset)
TRAY:
10 1/2" W x 10 1/2" D x 3 7/8" H
Designed for 6-96 tube well blocks.
Capacity, 5 to 7 lbs.

CONTROLS:

Analog Shaker

Speed knob, variable, 1 to 10 dial markings

On/Off switch

Timer knob, variable, 1 to 10 dial markings

 

Digital Shaker

Speed and time LCDs, Pulse feature, Timer (with automatic reset) runs from 1 sec up to 167 hrs or may be used in a continuous mode

 
OPERATION: Four knobs spin up to allow top tray removal. Replace top tray and tighten knobs after replacing blocks
PRODUCTS AND ACCESSORIES

Part Number

Description

Price

TR-945130

Analog Control 120 volt

$3320

TR-945135

Analog Control 230 volt

$3320

TR-945170

Digital Control 115 volt

$4150

TR-945175

Digital Control 230 volt

$4150

TR-945141

Replacement tray pad set

$56

TR-945143

Replacement Top Tray

$96

COMMENTARY

Like most laboratories, our research commonly uses 96 and 384-well plates. However the benefit of high-density formats for high throughput screening is often complicated by the inability to ensure that the samples within the wells are treated uniformly. Actions such as heating, cooling, and mixing often lack uniformity across microwell plates, and can add significant variation in the experimental results. The best example of this variation is the edge effect that plagues cell culturists. We have examined many of the variables affecting assays in microwell plates, and for assays requiring mixing we found that the Troemner Micro Plate Shaker provides vigorous uniform agitation for both cell growth and cell lysing. Unlike vortexing units, the Micro Plate Shaker generates a tight circular motion on multiple plates so that each well receives the same treatment. Even for something as simple as plasmid isolation, lack of uniformity in the lysis step can lead to considerable variation in yields. Consequently, we routinely use this high speed orbital shaker for many of our standard procedures using deep well and standard microtiter plates.

 


 

Home                             

Products                       

About Us                       

Contact Us                   

Links                             

 

 

 

 

 

OPS Diagnostics, LLC

672 Rt. 202-206 North

Building 3, Lower Level

Bridgewater, NJ 08807 USA

TEL: (908) 253-3444

FAX: (908) 575-1660

Email: info@btc-bti.com

Reviewed February 19, 2008